top of page

For Those Who Want to Increase Power Generation | 5 Improvements You Can Make After Installation

By LRTK Team (Lefixea Inc.)

All-in-One Surveying Device: LRTK Phone
text explanation of LRTK Phone

Solar power systems are not finished once installed. Even if careful consideration was given at the time of installation, dirt after the start of operation, shading, vegetation growth, equipment aging, wiring-related issues, and changes in the surrounding environment can reduce power generation. For practitioners who want to increase generation, the important thing is not to indiscriminately add equipment, but first to confirm whether the existing system is operating close to its intended performance. This article organizes five realistic post-installation improvement measures and explains ways of thinking that are useful for reviewing power output.


Table of Contents

• Basic principles to understand before increasing power generation

• Improvement 1: Visualize generation performance and isolate the causes of decline

• Improvement 2: Check the effects of dirt and shading on panel surfaces

• Improvement 3: Inspect wiring, connection points, and power conversion equipment

• Improvement 4: Manage solar radiation losses caused by vegetation and the surrounding environment

• Improvement 5: Understand the site's shape and equipment layout and use that information to inform improvement decisions

• Decision-making mistakes to avoid when improving power generation

• Summary: Understanding the site after installation is important for increasing power generation


Basic concepts to grasp before increasing power generation

When you want to increase power generation, the first thing to check is whether the current output is truly abnormal or simply a natural fluctuation due to seasonal or weather-related factors. Solar power generation is influenced by multiple factors such as solar irradiance, temperature, shading, soiling, and equipment condition. Therefore, even if generation is low on a single day, it is premature to conclude that there is a malfunction or defect. Conversely, if output is gradually declining month by month, or if it consistently underperforms compared with sections under the same conditions, there may be room for improvement at the site.


What is important in post-installation improvements is to understand the phrase “increase power generation” not as forcibly raising the equipment’s capacity, but as reducing losses and bringing performance closer to its inherent generation potential. Power generation equipment has a design limit. Since panel capacity, installation angle, orientation, and surrounding terrain are fixed, measures alone cannot increase generation without limit. However, by eliminating losses caused by dirt, shading, poor connections, overgrown vegetation, or equipment malfunctions, it may be possible to improve actual output.


Also, improving power generation is not something that can be completed in a single task. By continuously following the sequence of inspection, recording, comparison, isolating causes, taking countermeasures, and rechecking, you can stably manage the condition of the power plant. In particular, operations personnel need a perspective that checks what is happening on site, not just looking at the power output figures. A decline in power output can be caused by various issues hidden not only on the panel surface but also in the mounting structures, wiring, junction boxes, power conversion equipment, drainage, slopes, surrounding trees, and other locations.


Therefore, the first step to increasing power generation is to accurately assess the current situation. By combining and reviewing past generation data, weather, inspection records, site photos, equipment layout, and changes in the surrounding environment, it becomes clear where to begin. Narrowing down the causes before implementing improvements reduces unnecessary work and makes it easier to implement effective measures while minimizing the burden on the site.


Improvement Measure 1: Visualize Power Generation Performance to Isolate Causes of Decline

One of the improvement measures you can take after installation is to visualize the generation performance and isolate the causes of any decline. When you want to increase energy output, rather than immediately considering cleaning or equipment replacement, it is important to first check changes in generation over time. By looking at generation on a daily, monthly, and seasonal basis, it becomes easier to determine whether a decline is temporary or persistent.


For example, if generation decreases only during stretches of rain or overcast weather, the impact of the weather is likely significant. Conversely, if output remains lower than before even on sunny days, you should suspect soiling, shading, equipment faults, or wiring abnormalities. Also, if a power plant contains multiple sections or circuits, comparing each one's generation performance can help determine whether the problem is affecting the entire plant or is localized to certain parts.


When visualizing power generation, it is important not to rely solely on simple totals. Looking only at the total generation can mask localized issues. Trends such as only a specific circuit being low, drops during particular time periods, or extreme differences in the morning and evening may indicate shading or connection problems. Examining the numbers in detail makes it easier to prioritize on-site inspections.


Also, checking power generation records together with weather data and inspection records allows for more practical decision-making. If there was heavy rain, snowfall, yellow sand, fallen leaves, nearby construction, or similar on a day when generation dropped, the list of possible causes will change. Conversely, if output falls while there is no major change in the weather, inspection of the equipment side is necessary. Having on-site personnel record their daily observations is a great help when tracing the cause later.


When visualizing power generation performance, it is also effective to establish criteria for detecting anomalies quickly. By clarifying comparison targets—such as comparing with the same period in past years, with plots under similar conditions, or with generation trends on sunny days—you can make decisions based on data rather than on intuition. An impression that generation is low alone makes it difficult to prioritize countermeasures. By confirming trends numerically, it becomes easier to determine whether cleaning is needed, whether shading countermeasures are required, or whether equipment inspections should be prioritized.


Efforts to increase power generation begin with finding problem areas. Visualizing actual performance may seem like a mundane task, but it is the foundation for avoiding unnecessary measures and concentrating on improvements that are truly effective. At power plants after the start of operations, the habit of accumulating daily generation data and checking it against on-site conditions leads to maintaining generation levels over the long term.


Countermeasure 2: Check the effects of dirt and shadows on the panel surface

The second improvement measure is to check the effects of dirt and shadows on the panel surface. In solar power generation, when the sunlight reaching the panels decreases, power output also falls. If dirt is adhered to the surface, leaves or bird droppings remain, or shadows from surrounding trees and structures fall on them, they cannot receive the sunlight they should be getting. If you want to increase power output after installation, it is important to first check for visible losses on site.


Soiling on panel surfaces varies depending on the power plant’s location. Sites prone to airborne dust, locations near the sea exposed to salt‑laden winds, areas with many trees where leaves and pollen readily adhere, and places where birds tend to congregate are more likely to experience soiling effects. Some dirt will be washed away naturally by rain, but not all will be removed. If dirt remains on the lower edge of the panel or near the frame, it can lead to partial shading.


However, it is not as simple as cleaning immediately just because something is dirty. Cleaning requires safety management, and using incorrect methods can scratch panel surfaces or create hazards such as electric shock or falls. In high places, on steep slopes, or where scaffolding is unstable, a work plan tailored to site conditions is indispensable. Even when cleaning to improve power generation, it is important to prioritize safety and protection of the equipment and to carry out the work using methods that match the equipment specifications and site conditions.


Checking for shadows is also important. Even places that had no issues at the time of installation can develop shadows as the surrounding environment changes over time. Changes such as trees growing, weeds getting taller, structures being built nearby, or materials and equipment being placed around the mounting racks can cause unexpected shadows to fall on the panels. Especially in the morning and evening, when the sun is low in the sky, even brief shadows can extend over a wide area.


Shading can affect power generation more than it appears. Even if only part of a panel is shaded, depending on the connection configuration, the output of the affected section can be reduced. Therefore, during on-site inspections it is important to record not only whether shading is present, but also at what times of day, over what area, and for how long the shading occurs. Checking how shading appears in the morning, around midday, and in the afternoon makes it easier to correlate it with reductions in power generation.


Also, if a decline in power output is concentrated in specific times of day, it is worth prioritizing a check for shading. Patterns such as output being low only in the morning, suddenly dropping only in the evening, or declines that are more noticeable in certain seasons can be related to the sun’s position or the influence of nearby objects. Keeping fixed-point site photos makes it easier to grasp seasonal differences and changes caused by the growth of vegetation.


Dirt and shading on panel surfaces are relatively easy to detect as causes of reduced power generation, yet they are also items that are often neglected. By checking them regularly during routine inspections and comparing the findings with generation data, you can make timely decisions about the necessary countermeasures. Reducing losses caused by dirt and shading is a basic way to improve power output after installation.


Improvement 3: Inspect wiring, connection points, and conversion equipment

The third improvement measure is inspection of the wiring, connection points, and conversion equipment. Low power generation is not caused only by the panel surface or solar irradiance conditions. It is also important to check whether the electricity generated by the panels is being properly collected, converted, and transmitted. Loose wiring, deteriorated connections, equipment malfunctions, poor ventilation, or temperature increases can prevent the generated power from being fully utilized.


In inspections around wiring, it is important not to overlook visible abnormalities. Check for cable sagging, damage to the sheathing, loose fasteners, discoloration around connection points, signs of rainwater ingress, and damage caused by small animals. Power generation equipment installed outdoors is continually exposed to wind and rain, ultraviolet light, temperature changes, and contact with vegetation. Even if there were no problems at the time of installation, conditions can change gradually during long-term operation.


Connection points require particular attention. If connections are loose or contact is poor, resistance increases, which can lead to heating and reduced output. If a drop in power generation is concentrated in certain circuits, inspecting the connection points and wiring becomes important. However, inspections of electrical equipment involve hazards, so tasks that require specialized checks should be entrusted to qualified personnel or the appropriate responsible staff. Even if you want to increase power output, on-site personnel should avoid attempting to access the inside of equipment.


Checking the condition around the power conversion equipment is also essential. Power conversion equipment plays an important role in converting the generated direct-current (DC) power into a usable form. If the equipment experiences abnormal shutdowns or displays warning indicators, it can lead to a decrease in power generation. In addition, poor ventilation around the equipment, intake or exhaust being obstructed by vegetation or stored items, or an environment exposed to direct sunlight or prone to heat buildup can cause reduced efficiency or shutdown.


In practice, it is important to periodically check equipment displays and records to see whether there are any abnormal histories. If days of low power generation match the equipment’s warning history, it becomes easier to narrow down the cause. When abnormalities occur intermittently, the equipment may appear normal during on-site inspections. Therefore, it is important to review daily records and logs to determine when, on which equipment, and what kind of condition occurred.


Inspections of wiring and equipment are directly linked not only to improving power output but also to safety management. A decrease in power output can be a sign of equipment faults before they become apparent. By detecting minor abnormalities early, downtime can be shortened and long-term operational risks reduced. Inspections aimed at increasing power output are not merely to improve the numbers; they are fundamental maintenance activities to ensure stable operation of the equipment.


Improvement Measure 4: Manage solar radiation losses from vegetation and the surrounding environment

The fourth improvement is to manage solar radiation losses caused by vegetation and the surrounding environment. At ground-mounted solar power plants, the growth of weeds and trees can affect power generation. Even if there is no problem immediately after installation, over months and years vegetation can grow, casting shadows on panels, blocking inspection walkways, or coming into contact with wiring and mounting racks. If you want to increase power generation, vegetation management cannot be overlooked.


The shadows of vegetation can be overlooked on site as a cause of reduced power generation. In particular, for panels installed at low positions, even a slight growth of weeds in front can cast a shadow on the lower edge of the panel. Even if the shadow appears small, it can still affect power generation. When mowing or implementing weed control measures, it is important to manage not only for appearance but also by considering the sun’s movement and how shadows lengthen.


Also, the priority of vegetation management changes with the seasons. During periods of rapid growth, areas that were not a problem at the previous inspection can become sources of shading in a short time. If reductions in power generation recur in a particular season, you should check for the effects of vegetation growth or leaf fall. Keeping site photos by season makes it easier to understand which times of year and which locations are prone to problems.


You also need to pay attention to changes in the surrounding environment. If new buildings or facilities are constructed nearby, temporary structures or materials are placed, or trees around fences grow, shadows that were not anticipated at the time of installation can occur. If you only look at the power plant site, you may overlook shadows coming from outside the premises. To increase power generation, you need a perspective that checks not only the equipment itself but also the surrounding environment.


In managing vegetation and the surrounding environment, securing inspection routes is also important. If inspection pathways are covered with grass, workers may find it difficult to move safely, and checks of the back of panels and around wiring can be inadequate. When drains and slopes are obscured by grass, it also becomes harder to notice rainwater flow and sediment accumulation. Improving power generation is related not only to ensuring sunlight but also to maintaining conditions that make inspections easy.


Furthermore, drainage and ground conditions also affect maintaining power output. In locations prone to puddles or mud, managing the area around the mounting structures becomes difficult, which can lead to overgrown vegetation and inadequate inspections. If slope failures or soil erosion occur, they may cause equipment to tilt and create problems with access routes. To increase power output, it is important not to focus only on the panels but to carry out maintenance and management of the entire power plant.


Losses caused by vegetation and the surrounding environment are easy to control with daily maintenance, but if left unattended they can have widespread effects. To prevent a decline in power generation, it is important to regularly check for changes at the site and promptly remove any elements that could cause shading.


Improvement Measure 5: Understand the site's shape and equipment layout and use it to inform improvement decisions

The fifth improvement measure is to accurately understand the site's topography and equipment layout and to use that understanding when making improvement decisions. Measures to increase power generation cannot be determined by data alone. Only after grasping the site's slope, panel arrangement, racking height, access ways, drainage, surrounding objects, and the way shadows fall can you judge which measures will be effective. In particular, for large power plants or sloping sites, it can be difficult to understand the overall condition of the site from two-dimensional drawings or photographs alone.


At power plants after installation, the current conditions do not always match the original plans exactly. Adjustments during construction, changes in the ground, additions of nearby equipment, alterations to maintenance access routes, and growth of vegetation all cause the site to change gradually. To identify the cause of a decline in power output, it is important to accurately grasp the present equipment layout and surrounding environment. If countermeasures are carried out without confirming the current conditions, the work may be misaligned with the actual cause and may not produce sufficient effect.


For example, if only one section has lower power generation, you should not only inspect the panel surfaces and equipment in that section, but also check the surrounding terrain and sources of shading. On sloped sites, even within the same plant, sunlight conditions, water runoff, and grass growth can vary by location. Rows located at lower elevations can be more prone to shading from the rows in front, embankments, or nearby trees and shrubs. By grasping the three-dimensional on-site conditions, you can consider the causes of reduced power generation more concretely.


Also, recording the site's layout and conditions helps when comparing before and after improvements. After carrying out vegetation removal, cleaning, drainage improvements, pathway maintenance, relocation of surrounding objects, and so on, checking how power generation and shading conditions have changed makes it easier to verify the effectiveness of the measures. Rather than ending once improvements are implemented, confirming the on-site conditions together with the generation data makes it easier to establish the next management plan.


Understanding the equipment layout also contributes to more efficient inspection and maintenance. Organizing which circuits are located where, which devices they are connected to, and from which walkways they can be safely inspected will enable faster response when an anomaly occurs. If, when power generation decreases, you can immediately verify the affected area on site, you can more easily reduce downtime and investigation time. In efforts to increase power generation, the speed of identifying the cause is also an important factor.


When conducting on-site surveys, records that include location information are effective, not just photos and drawings. By recording where dirt is most noticeable, where shadows appear, which places are prone to vegetation growth, and which pieces of equipment showed abnormalities—along with their locations—you can improve management accuracy. Even if the person in charge changes, organized records make it easier to hand over past response histories and areas of concern.


To increase power generation, it is essential not to assess the site by intuition but to record conditions and make them comparable. By obtaining a three-dimensional understanding of the plant’s current condition and managing it in conjunction with generation data, you can more reliably carry out post-installation improvements.


Errors in judgment to avoid when improving power generation

When aiming to increase power generation, be careful not to rush into countermeasures without first confirming the cause. If you perform cleaning based only on the result that power generation is low, and the cause is equipment malfunction or shading, it may not lead to the expected improvement. Conversely, if you suspect an equipment fault and proceed with inspections, it may actually have been a temporary weather issue or a seasonal variation. When improving power generation, it is important to make judgments by combining numerical data, on-site inspection, and historical records.


Also, it’s important to avoid judging based solely on short-term generation figures. Solar power generation is heavily affected by the weather, so just a few days of performance may not reveal accurate trends. You should check under as similar conditions as possible—compare sunny days with other sunny days, compare with the same period in past years, or compare with nearby plots under similar conditions. When you feel the generation is low, it’s all the more important to calmly organize and clarify your comparison targets.


Be cautious of excessive expectations. Post-installation remedial measures are intended to recover lost generation opportunities; they are not meant to dramatically increase output beyond the design conditions. Therefore, when considering the effectiveness of improvements, you need to determine what is causing the losses and roughly how large those losses might be. Expecting large effects without a clear understanding of the causes will make it difficult to evaluate the results after measures are implemented.


Safety must not be neglected. Panel cleaning, mowing, wiring checks, and equipment inspections all involve on-site work. There are hazards when working on slopes, at heights, in mud, in high temperatures during summer, and near electrical equipment. Even if the aim is to increase power generation, prioritizing worker safety and protecting equipment is a prerequisite. In particular, inspections involving electrical equipment should be handled by personnel with specialized knowledge as necessary.


Furthermore, measures that leave no record can also lead to incorrect judgments. It is important to record not only the fact that cleaning, mowing, or inspections were performed, but also when, where, what condition they were addressing, and what was done. Without records, it becomes difficult to verify later whether power generation actually improved. Organizing before-and-after photos, generation data, work details, and on-site observations will improve the accuracy of future decisions.


Improving power output is not a one-off task but part of operations management. To reduce judgment errors, it is important to establish a process of isolating causes, inspecting the site, keeping records, and verifying effectiveness after countermeasures. Once this process is established, you will notice declines in power output sooner and be able to implement necessary measures without undue strain.


Summary: Understanding on-site conditions after installation is crucial for increasing power output

For operations personnel seeking to increase power generation, the first thing to tackle is not adding equipment but verifying whether the current plant is performing as it should. Reductions in generation are caused not only by weather and seasonal variation but also by various factors such as dirt on panel surfaces, shading, vegetation growth, abnormalities in wiring and connections, malfunctions around conversion equipment, and changes in the surrounding environment. By isolating these factors one by one, opportunities for improvement even after installation become apparent.


Effective improvement measures start with visualizing power generation performance. By checking daily and monthly generation and comparing it with the same period in the past or with sections within the same power plant, it becomes easier to determine whether there are any abnormalities. On that basis, it is important to check panel surface soiling and shading, inspect wiring, connection points, and power conversion equipment, and manage solar irradiance losses caused by vegetation and the surrounding environment. Furthermore, understanding the site's topography and equipment layout makes it easier to identify where problems lie and which countermeasures should be prioritized.


When improving power output, it is important not to rely solely on intuition. By combining and checking generation data, on-site photos, inspection records, location information, and equipment layout, you can narrow down the causes concretely. After implementing countermeasures, verify how the power output changed and record the effects of the improvements so they can be used in future management. Because a power plant’s environment continues to change after installation, regular on-site assessment and consistent record-keeping contribute to long-term maintenance of power output.


One of the quickest ways to increase power generation is to accurately understand site conditions and reduce the causes of loss. At large plants, on sloped sites, or where equipment layouts are complex, the more you have a system to accurately capture current conditions, the higher the accuracy of inspections and improvement decisions. If you want to more reliably advance post-installation improvements in power generation, it is important to link generation data with on-site records and establish a management method that can be used for root-cause analysis and verification after countermeasures.


Next Steps:
Explore LRTK Products & Workflows

LRTK helps professionals capture absolute coordinates, create georeferenced point clouds, and streamline surveying and construction workflows. Explore the products below, or contact us for a demo, pricing, or implementation support.

LRTK supercharges field accuracy and efficiency

​

The LRTK series delivers high-precision GNSS positioning for construction, civil engineering, and surveying, enabling significant reductions in work time and major gains in productivity. It makes it easy to handle everything from design surveys and point-cloud scanning to AR, 3D construction, as-built management, and infrastructure inspection.