top of page

In solar power plant construction, attention tends to focus on racking, foundations, panel installation, and the installation of electrical equipment, but in practice the quality of conduit work greatly affects subsequent constructability, maintainability, and long-term stable operation. Conduits are not merely passageways for cables. In outdoor environments exposed to rainwater, they protect cables, stabilize connections between equipment, and are the very infrastructure that supports future inspections and upgrades. However, on site the work often falls on the boundary between civil and electrical scopes, making it unclear who is responsible for finalizing routes, and rework later is not uncommon.


Especially for practitioners gathering information under the keyword "solar power plant construction", what matters is not installing conduit exactly as shown on the drawings, but translating that into a conduit plan that will not fail on site after taking into account the local topography, rainwater flow, movement lines of heavy machinery and maintenance vehicles, equipment layout, and future maintenance. Even sites that appear flat can change the way water accumulates after site preparation, and a slight shift in the location of a conduit riser can make equipment connections difficult. Deciding burial depth and how bends are handled too lightly can increase snags during cable pulling and cause unnecessary stress on the cable after it has been drawn in.


In this article, we organize and explain six key points that on-site personnel should particularly keep in mind when carrying out piping work during solar power plant construction. Following the practical workflow, we clearly summarize the points to check at the design stage, issues that are easy to overlook during construction, and an approach that anticipates maintenance after completion.


Table of Contents

• Why piping work is important in solar power plant construction

• Key point 1: Decide the piping route together with racking, foundations, and the drainage plan

• Key point 2: Select burial depth and protection methods according to site conditions

• Key point 3: Plan anticipating rainwater, groundwater inflow, and ground deformation

• Key point 4: Do not compromise conduit passability or future maintainability

• Key point 5: Do not be lax about the detailing of risers, connections, and penetrations

• Key point 6: Do not postpone as-built control and construction record-keeping

• Summary


Why Piping Work Is Important in Solar Power Plant Construction

Piping work for solar power plants is a foundational process that, while not easily visible, determines the overall quality of the site. This is because solar power plants tend to have equipment spread over a wide area and, even when ground-mounted, are exposed to harsh outdoor environments for long periods, so the role required of piping becomes broader than that of typical building services. In addition to safely collecting and conveying power, the planning and execution of piping are closely related to preventing cable damage, ensuring waterproofing around equipment, reducing the risk of contact during grass cutting and inspections, and making replacement work easier in the event of a failure.


Also, at solar power plants multiple trades—civil works, mounting structures, electrical, site formation, and drainage—operate on similar timelines. Therefore, if piping work is treated as a standalone task, inconsistencies are likely to occur. For example, a piping route decided earlier may conflict with foundation positions or side-ditch locations; ground elevation may change after site formation so the vertical riser length no longer fits; or pipes may be buried too shallowly where they cross a maintenance access, resulting in insufficient consideration for vehicular loads. These issues not only require redoing the piping itself but also draw in surrounding equipment and the scope of restoration, delaying the entire schedule.


Furthermore, defects in solar power plants often surface not immediately after handover but after seasonal changes, heavy rainfall, ground settlement, and repeated temperature fluctuations. Even if no problems are visible during construction, months later components may become exposed by erosion, undue stress at riser sections can cause cracking or loosening, and insufficient allowance for cable pulling can become an obstacle to expansion or upgrades. In short, piping work cannot be judged solely by how it fits on site; it must be considered in terms of whether it will withstand long-term operation.


For field personnel to avoid failures in piping work, it's important not just to follow the lines on the drawings but to anticipate and organize "where loads will be applied," "where water will accumulate," "where openings may need to be made in the future," and "who on site will perform the work and in what sequence." Below, we will look at six particularly important points to that end, in order.


Key point 1: Determine piping routes together with supports, foundations, and drainage planning

The first thing to keep in mind in piping work is not to finalize the route based solely on electrical drawings. At a solar power plant, piping shares the same surface or underground space with many elements such as racking rows, foundations, collector equipment, substation equipment, on-site access paths, and drainage facilities. Therefore, if the piping route is laid out in advance only by the electrical team, clashes with other trades are likely to be discovered later, resulting in forced bends or changes to risers.


Particular attention should be paid to the finished ground elevation and the direction of drainage. Even a route that appears straight and rational on the drawings can, on the actual site, coincide with subtle undulations where water tends to collect. As a result, after burial it may be prone to scour or settlement, which is disadvantageous from the perspective of pipe protection. Conversely, by shifting the route slightly you may be able to avoid rainwater flow paths and place it in a position that is easier to construct. Therefore, when planning the route it is essential to check not only the plan view but also the longitudinal elevation differences and their relationship to drainage outlets.


Coordination with support-structure foundations and equipment foundations is also important. Near foundations, excavation, compaction, concrete placement, and constraints on anchor locations overlap, so if there is insufficient clearance for pipe routing the construction sequence will be disrupted. The management approach also differs depending on whether you intend to install piping immediately after the foundation work or to set out positions with advance piping. Furthermore, routing too close to foundation corners or edges can affect excavation stability and backfill quality, and may lead to surface irregularities or settlement after the ground has settled. These points should be decided by prioritizing the overall safety and repeatability of the construction rather than the shortest distance shown on the drawings.


When planning pipe routes, don't forget to consider maintenance access. Even after a solar power plant begins operation, people and vehicles will enter for inspections, weeding, washing, equipment replacement, and other tasks. Pipes that cross locations frequently used by people or vehicles are therefore more susceptible to external forces. Even when crossings are unavoidable, you must decide whether to concentrate crossings in one location and reinforce protection, or to distribute them across multiple locations to reduce the impact. Establishing rules that are easy to manage on site makes decisions during construction less likely to vary.


Furthermore, when planning routes, taking future expansions and renovations into account can greatly change the degree of freedom after completion. Even if they seem unnecessary in the initial plan, additions such as monitoring equipment, updates to measurement wiring, or equipment replacements may require new wiring routes. If conduits are packed into the tightest possible positions, later renovations may require re-excavation and affect equipment that is in operation. Allowing even a small margin during the construction phase will significantly reduce the burden after operations begin.


In other words, in solar power plant construction it is important to treat conduit routes as an infrastructure plan that reflects the use of the entire site, rather than merely as connection lines for electrical equipment. Deciding routes not only by coordinating drawings but by simultaneously considering site preparation, drainage, foundations, maintenance access routes, and future retrofits will lead to conduit work with minimal rework.


Note 2: Select burial depth and protection methods according to site conditions

In piping work, the assumption that burial alone ensures safety is dangerous. Burial depth and protection methods should not be decided solely by the cover depth figure; they need to be determined by considering overlying loads, ground conditions, surrounding operations, and future maintenance activities.


Solar power plant sites are not only flat ground but also include reclaimed or filled land, areas near slopes, maintenance tracks surfaced with crushed stone, soft ground, and ground mixed with cobbles or boulders, so conditions are diverse and the appropriate level of protection varies by location.


For example, beneath routes used by maintenance or construction vehicles, simply burying pipes shallowly makes them vulnerable to the effects of repeated loading. Even if there are no issues at the time of installation, ground consolidation over time can transmit localized loads to the piping, increasing the risk of deformation or damage. Conversely, in locations dominated by pedestrian traffic where external forces are small, excessive excavation or overprotection can actually reduce construction efficiency. The important point is not to treat the entire site with a uniform specification, but to differentiate the approach according to the expected usage conditions.


In areas with many boulders and crushed stone, the choice of backfill material is also important. If hard stones are allowed to bear directly against the pipe when backfilling, even if there are no abnormalities immediately after construction, ground settlement or vibration can cause stresses to concentrate at the point-contact areas. Materials with stable shapes should be used around the pipe, and they must be placed so that localized loading does not occur. This is a mundane task, but precisely because it will be out of sight, differences in construction quality tend to appear. Because it cannot be inspected after backfilling, management during construction and photographic records are essential.


Also, when it is unavoidable to lay piping close to the ground surface, the challenge is how to reduce the risk of exposure and third-party contact. At sites where topsoil is washed away by rain after development, the initially assumed soil cover may not be maintained. Extra care is especially needed near slope shoulders and at locations where water flow converges. In such places, it is realistic to consider a combination of measures—not simply increasing depth, but also changing the route, adding protective materials, and stabilizing the ground surface. Do not rely on burial depth alone; adopt an approach that evaluates changes in the terrain after completion as well.


In cold regions and sites with large elevation differences, consideration for seasonal changes is also necessary. In locations subject to frost heave or repeated wetting and drying, soil movement around pipes increases and can affect joints and risers. Also, in sections where exposed, sunlit parts and buried parts coexist, you must be aware of differences in thermal expansion and contraction behavior due to temperature differences. If you fix them too rigidly, stresses cannot be relieved; if you allow too much play, misalignment occurs. The transition points between buried and exposed sections are areas where the detailing should be considered particularly carefully.


Furthermore, protective measures are more effective when you consider not only the pipes themselves but also the visibility of the surface and surrounding area. Keeping pipe locations easily identifiable for site management to avoid accidental damage during future excavation or repair work contributes to long-term operational safety. Because solar power plants often require various repair works even after they begin operation, ambiguous information about buried items can lead to secondary disasters.


In short, matching burial depth and protection methods only to the figures in the specifications is insufficient. You must set protection levels based on how the site is used, ground conditions, rainwater, and future work, and vary the installation approach according to the risks at each location—this is the basic way to prevent failures in piping work.


Precaution 3: Plan in anticipation of rainwater, spring water, and ground deformation

One aspect that is often overlooked in pipework for solar power plants is the influence of water and ground conditions. On large outdoor sites, areas that appear dry at the time of construction can change dramatically during heavy rain or seasonal shifts. The direct causes of pipe failures are not limited to material defects or poor workmanship; unexpected water flows or ground movement often act as triggers. For this reason, it is important not to treat pipework separately from civil engineering planning and drainage planning.


First, be aware that land development can alter natural drainage routes. Even areas that were not problematic in the pre-construction topography can become water pathways along pipelines when grading, embankments, slope formation, or the installation of access paths change how water collects. Excavated and backfilled portions tend to have different soil compaction than the surrounding ground, making them more prone to water flow and potentially becoming initiation points for scouring and settlement. This tendency is especially pronounced for long straight pipelines and pipelines aligned with the slope, so care is required.


In low-lying areas, valley-like terrain, and at the boundary between embankments and cut slopes, not only rainwater but also the effects of spring water cannot be overlooked. Locations where water seeps into excavation faces during construction may be affected by groundwater levels and infiltrating water even after completion. If the standard installation details are forced on such sites, backfill material may be washed out and voids may form, causing unstable pipe support conditions. Insufficient support leads to deflection, settlement, and tensile stresses at joints, which will manifest as defects later. Even if the pipe itself appears sound, it will not be durable if the surrounding ground behaves poorly.


Also, the boundary between equipment foundations, pavement, and crushed stone bedding is a point where ground deformation tends to occur. At locations where different structures meet, the way rainwater flows and how loads are transmitted change, making differential settlement more likely. If piping crosses that boundary, bending and tensile forces tend to concentrate when only one side settles. In such areas, rather than relying solely on the strength of the pipe itself, it is necessary to consider the stability of the surrounding ground, support methods, and provisions for movement. If riser sections or equipment connection points are nearby, planning should be even more careful.


The effects of water are not limited to buried sections. At riser sections and around equipment, rainwater running over surfaces can flow down along piping. If water enters the interior through even a small gap, it can adversely affect cables, terminals, and equipment internals. For outdoor installations, waterproofing must consider not only rain from above but also splashback from the ground, puddles, and condensation. A single decision about piping orientation, slope, connection location, or sealing strategy can greatly change how easily water can enter.


In practice, it is crucial not to judge based only on how things look on a clear day. During on-site inspections, it is important to carefully pick up clues that allow you to imagine post-rain conditions — such as locations lower than the surrounding ground, traces of existing flow channels, traces of fine sediment having flowed, the way grass has been flattened, and moisture at the bottom of slopes. If possible, sorting out in advance with the civil engineering team "where to divert the water," "where to allow crossings," and "which areas to avoid" will make decisions about piping work more stable.


Solar power plants are put to the true test not at the moment of completion but during the rainy season and typhoons. That is why, in piping work, it is important not to focus only on the pipes but to assemble routing, supports, backfilling, and waterproofing assuming changes in water and ground conditions. If this is neglected, the installation may look neat immediately after construction but could require repairs involving excavation a few months later.


Point 4: Do not compromise cable passability and future maintainability

On piping work at solar power plants, there are cases where people become complacent simply because the piping has been installed during construction. However, the true quality of the piping is determined by whether cables can be pulled through without strain and whether future inspections and replacements will be easy. Even piping that looks neat on the outside can place a heavy burden during cable pulling and compromise the safety and quality of on-site work if it has too many bends, a cramped riser location, or makes pull-in operations difficult.


First, the important point is how you think about bends. If you make many small bends in the conduit on the plan to follow obstacles, pulling resistance tends to increase. Especially on long runs, the accumulation of small bends becomes a significant work burden. Applying strong force during cable pulling puts unnecessary stress on the cable jacket and conductors and can lead to invisible damage. Therefore, during the route planning stage it is important to secure as straight a path as possible, and where direction changes are unavoidable, to allow generous clearance and detailing that anticipate later work.


Also, the way to think about conduit diameter is not simple. If you choose a conduit size that just barely matches the number of cables you currently plan to run, not only will cable-pulling become difficult, but flexibility for additional wiring or replacements will be lost. In solar power plants there are cables that may change from the initial plan, such as monitoring systems, communication systems, grounding-related wiring, and measurement systems that may be added in the future. If you cut back on spare capacity just to reduce initial costs, later renovations may require adding conduits or re-excavation, resulting in a greater burden on-site. Leaving even a little room for future changes directly translates to easier maintenance.


Additionally, securing positions where inspections or cable pulling can be performed is important. Planning to run a long section in one go looks neat, but if a blockage or damage occurs midway, diagnosing the cause and restoring service becomes difficult. Conversely, if you provide easily accessible checkpoints at appropriate locations, it becomes easier to perform quality checks during construction and inspections during operation. The important thing here is not to increase the number, but to think about where placing them will be helpful in the future. Planning them at meaningful locations—near equipment, at changes of direction, or partway through long runs—improves manageability.


From the standpoint of maintainability, it is also important that the locations of underground conduits are easy to identify. Since a solar power plant undergoes multiple tasks after completion, such as weed control, repairs, and equipment replacement, if the positions of buried conduits are unclear, careful trial excavations and surveys will be required each time. This is not only a cost and schedule issue but also a safety management issue. It is important to keep things clear so that future personnel can understand which equipment connects to which, at what depth ranges, and with what clearance the conduits are routed.


On-site at solar power plants, the busyness of construction work often leads to the mindset of "as long as it connects, that's fine." However, conduits with poor cable-pulling characteristics not only make on-site work difficult but also complicate troubleshooting after completion. Because equipment is used for a long time, having the perspective of whether the conduits will be easy for anyone to handle in the future—not just whether they fit at the time of installation—leads to higher-quality sites.


Note 5: Do not underestimate the detailing of upstands, connections, and penetrations

Defects in piping work tend to occur more often at change points such as riser sections, connection points, and penetrations than in straight buried sections. In solar power plants there are many locations where underground piping connects to aboveground equipment, and because these points are exposed to outdoor conditions—temperature changes, wind, rain, vibration, and ground movement—the detailing at such change points is extremely important. Even if the main piping is installed carefully, if the end detailing is inadequate the overall reliability will drop dramatically.


First, at the riser section, because it switches from a stable condition underground to a condition that is more exposed to external loads above ground, stress tends to concentrate. The above-ground portion is subjected to various forces such as mowing operations, contact during maintenance, flying debris, and minor impacts. Moreover, even a slight settlement of the ground can readily cause bending at the base of the riser. Therefore, the riser location should not be chosen simply because it is close to the equipment; it must be placed where it is less likely to be subjected to external forces and is easy to protect. In particular, locations along walkways or where work is concentrated have a higher risk of later damage.


At connection points, it is important to achieve both waterproofing and stress relief. Around outdoor equipment, if you focus too much on keeping water out and rigidly fix everything, there will be no room to accommodate temperature changes or ground movement, and cracks or loosening can occur elsewhere. Conversely, if you allow too much movement, sealing and support will be inadequate. On site, this sense of balance is critical and must be considered together with the support conditions of the connected equipment and the surrounding structures. Prioritize details that avoid long-term stress over merely a neat appearance.


Penetrations are also a point that must not be overlooked. At locations where foundations, slabs, enclosure materials, or shielding materials are penetrated, insufficient gap sealing can easily become a route for rainwater, dust, and small animals to enter. In addition, if piping or cables are in contact with the edge of a penetration, repeated micro-vibrations and temperature changes can accelerate wear. Even if there appears to be no problem at the time of installation, over the long term this can cause sheath damage or a reduction in insulation. Penetrations should be treated not as mere hole-making but as a detail design issue that includes protection, securing, sealing, and inspectability.


Furthermore, around equipment, attention must be paid to the relationship between the direction of drainage and the orientation of piping. When piping runs directly down into equipment, water that travels along surfaces can tend to collect at the connection points. Because slight differences in angle or height change how water accumulates, the final routing of piping should be decided not only on whether it will fit but also on how water will flow. In particular, for outdoor panels and junction boxes you should also anticipate splash and mud thrown up from the ground.


As such, the way change points are finished tends to reflect differences in on‑site experience. To improve the quality of piping work, you should spend time on how you handle riser sections and connection points rather than on long straight runs. If these are finished carefully, typical defects such as leaks, loosening, damage, and difficulty in inspection can be greatly reduced. In solar power plant construction, a few centimeters at the ends (a few in), a few degrees of orientation, and a slight allowance for clearance can determine the maintenance burden several years later.


Point 6: Do Not Postpone As-built Management and Construction Records

In piping work at solar power plants, many parts become invisible once buried, so the quality of as-built management and construction records directly determines future maintainability. Nevertheless, when sites get busy, record-keeping is often postponed, and after completion only vague information remains, such as “the pipe should run roughly around here.” This causes significant problems for inspection and repair after commissioning. The less visible the equipment, the more important it is to consciously leave information in a visible form.


First, it is important to decide in advance what to record before and after burial. Information you will later want to know—such as the piping route, branch locations, depths, crossing locations, riser positions, connection points, protection methods, and the condition before backfilling—is generally predictable. If photos and records are taken based on each site staff member’s own judgment, necessary photos can be missed or, even when taken, the positional relationships may be unclear. Therefore, it is essential to agree before work begins on which scenes to document and how to document them. This matters not only for quality control but also for the consistency of the handover documentation.


Next, it is also important not to leave drawing revisions as temporary fixes. In solar power plants, it is not uncommon to fine-tune piping routes and riser locations to suit site conditions. In fact, sites with no changes at all are relatively few. The problem is when those changes are communicated only verbally. Even if the construction team understands, the maintenance staff who only look at the drawings after completion will not be informed. When field changes occur, organize them so that the reasons and the actual positional relationships can be traced, which will prevent confusion after handover.


Also, in as-built management, "location accuracy" is more important than you might imagine. Solar power plants cover large areas and feature repetitive equipment layouts, so photos alone can make it difficult to pinpoint locations. If it is not clear which row, which block, and which piece of equipment a conduit connects to, the records lose their value. If you can organize records with accompanying location information, avoiding future excavations, planning expansions, and isolating faults becomes markedly easier. Ideally, there should be a system that can effectively link and preserve point clouds, positioning results, site photos, and as-built drawings.


Furthermore, construction records are not only for responding to the client or for internal sharing. They are also an asset for leveraging the accumulation of small on-site decisions on future projects. For example, changing a route where water tended to collect, strengthening protection at upstands, and devising details at crossings of maintenance walkways — each of these contributes to standardization for subsequent projects. If records are not kept, the same mistakes and rework are more likely to be repeated.


The construction quality of a solar power plant cannot be judged solely by its appearance at completion. For unseen piping in particular, records are the evidence of quality. That is why as-built management and construction records should not be tasks compiled at the end, but carried out concurrently as part of the construction process. The information reliably recorded on site becomes the foundation that supports future safety, maintenance efficiency, and the accuracy of repair and upgrade decisions.


Summary

Conduit and piping work in solar power plant construction is not merely an ancillary task. From route planning, burial depth, and protection methods to water countermeasures, cable routing, end terminations, and as-built management, it is a core process that determines the overall quality of the site. Especially for solar power plants intended for long-term outdoor operation, the attitude of “if it fits here it’s fine” is insufficient; construction must be carried out with an eye to heavy rainfall, ground changes, maintenance activities, and equipment renewal.


The six items introduced here are not anything special; they are basic points that tend to make a difference on actual job sites. Coordinate piping routes in conjunction with other trades, vary the level of protection according to burial conditions, anticipate changes in water and ground conditions, ensure ease of cable pulling and maintainability, carefully finalize the detailing of risers and connection points, and accurately record the as‑built condition before it becomes concealed. Simply and consistently implementing these measures can greatly reduce the risk of rework and problems after startup.


In recent years in particular, there has been growing demand in solar power plant construction to perform position checks and as-built verification more accurately during construction. If you want to quickly confirm pipe routes and equipment locations on site and improve recording accuracy with an eye toward subsequent work and maintenance, it can be effective to review your positioning methods. For example, by using an iPhone-mounted GNSS high-precision positioning device such as LRTK, you can more efficiently carry out on-site positioning, as-built verification, and recording of buried routes. Because piping work becomes hidden, it is important to leave information that prevents confusion later. If you want to raise the construction quality of a solar power plant, review not only the physical arrangement of the piping itself, but also how you measure on site, how you record it, and how you link it to the next process.


Next Steps:
Explore LRTK Products & Workflows

LRTK helps professionals capture absolute coordinates, create georeferenced point clouds, and streamline surveying and construction workflows. Explore the products below, or contact us for a demo, pricing, or implementation support.

LRTK supercharges field accuracy and efficiency

​

The LRTK series delivers high-precision GNSS positioning for construction, civil engineering, and surveying, enabling significant reductions in work time and major gains in productivity. It makes it easy to handle everything from design surveys and point-cloud scanning to AR, 3D construction, as-built management, and infrastructure inspection.

bottom of page